Electric motor NVH simulation from electromagnetic force to stator vibration, housing noise and whine
The motor is quiet on average and still whines at one speed. Radial force, stator modes and housing radiation show which tone comes from the electromagnetics and whether the cure is in the design or in the control.

Electric motor NVH simulation predicts which tones an electric machine radiates, which of them come from its electromagnetic forces, and what a design or a control change does to them. We build it around your existing electromagnetic and structural solvers, with a validation record and a surrogate of stated range, so a whine is found and fixed on the model, before the first sample reaches the dyno or the vehicle.
The motor is quiet on average, and still there is a tone at one speed that makes the whole drive sound wrong. Siemens puts the cause plainly: an electric powertrain is not silent. The overall levels are lower, but the high-frequency, tonal content is annoying, from higher motor orders due to the construction, very high frequency sounds, off-zero orders and lines related to the PWM switching frequency. With no engine to mask them, motor whine and gear whine stand out. Waiting on the answer: the NVH sign-off, the slot and pole choice, the control calibration and the first build.
- Radial force. The force between rotor and stator acts across the air gap. It does not contribute to energy conversion, but it generates vibration, and in a Volvo CE e-motor study it was much higher than the tangential force.
- Tangential force and torque ripple. It contributes to the average torque and, through torque pulsation, to noise and vibration.
- Stator ring mode. The force on the teeth is applied to a flexible stator and housing. Where its frequency meets a natural frequency, the stator responds strongly, so the structure decides how much of the force becomes vibration.
- Radiating housing. Vibration of the housing surface radiates sound, with clear order characteristics. Without an engine to mask them, tones such as motor whine stand out.
- Inverter carrier. A circuit-coupled transient analysis can include the carrier harmonics from the power electronics converter, which add their own lines to the spectrum.
Where does the noise of an electric motor come from?
Ansys names electromagnetic forces as the major cause of unpleasant sound from electric machines, and splits them in two. Radial force does not contribute to energy conversion, and it generates vibration. Tangential force contributes to the average torque and, through torque pulsation, to noise and vibration. Rotor and fan aerodynamics and imperfect mechanical assembly add to the picture, and a good model keeps them in view.
The relative size matters when you decide what to fix. In a Chalmers and Volvo CE study of a permanent magnet motor for electric construction machines, the radial force on the stator teeth at 2000 rpm and 425 Nm was significantly higher than the tangential force, because the flux lines are more concentrated in the radial direction. The same thesis starts from a practical complaint: the motor-driven machine had a different noise profile, with a dramatic increase in high-frequency noise in the range to which human hearing is sensitive, and operators felt uneasy.
How does force become vibration?
Through a structure that has natural frequencies. The force has to be carried from the electromagnetic mesh to the structural mesh, and the two usually differ. In the Siemens workflow the 2D forces are extruded into 3D and mapped onto the structural model, loaded onto the flexible stator teeth by rotor angle and speed, and the modal participation factors of the stator give the structural response to both the electromagnetic and the mechanical excitation. The housing, the bearings and the mounting are part of the model, because, as Ansys notes, they decide the natural frequency and the damping.
The Chalmers study shows what that looks like in numbers you can act on. The acceleration response is directly affected by the electromagnetic forces on the stator teeth. Within the speed range studied the amplitude fell as speed rose, because the back-emf changes the forces, and a smaller air gap lowered the acceleration amplitude. The author is careful to add that it did not change the emitted noise significantly: a smaller response of the structure is not the same thing as a quieter machine.
How far can you trust a radiated-noise estimate?
As far as its assumptions reach. The equivalent radiated power, a quick estimate from the surface velocity, is good for locating the frequency at which the maximum sound is emitted. The thesis states its limit: it is accurate only up to the first resonance, because after it an acoustic short circuit occurs. Beyond that frequency you need the acoustic model of the radiating surface, which is what the high-fidelity workflows provide. Saying where an estimate stops is part of the result.
What does the inverter add?
Its own lines. A circuit-coupled transient analysis can include the carrier harmonics from the power electronics converter, as Ansys describes, and Siemens uses the example of a random carrier frequency PWM to show how control choices balance switching noise and vehicle performance. That makes the noise problem part design and part calibration, and the model that carries both is the one that lets the motor team and the controls team change the same variable on the same day.
- Concept path. Forces estimated from the electrical model and the control currents, a simplified structure and a point-source noise model give an early, qualitative risk assessment at the concept stage, as in Siemens' system-level approach.
- Detailed path. A current-driven electromagnetic finite element model gives the forces, for example from the Maxwell stress tensor over the air gap, and a structural model of stator, housing and mounts carries them to vibration.
- Mapping. The electromagnetic and structural meshes usually differ, so the forces are mapped between them; in one workflow the 2D forces are extruded into 3D and applied to the stator teeth by rotor angle and speed.
- Acoustic step. Surface vibration gives radiated sound power. In the Volvo CE thesis the equivalent radiated power estimated the frequency of the loudest radiation, but was reliable only up to the first resonance.
- Measured check. Either path is judged against what a test shows: the order lines of the machine against speed. That is where its limits are found.
Which NVH question needs which path?
Both paths exist for a reason. In the Siemens concept stage a system model gives forces from the electrical model and the control currents, a simplified structure and a point-source noise model, as an early, qualitative risk assessment at the concept stage. The Ansys fast workflow takes the airgap forces from the Maxwell stress tensor and an analytical mechanical and acoustic model, and needs only a few minutes to predict the noise over a full speed sweep. The detailed path maps forces onto structural finite elements and solves the vibroacoustics for the design that is going to be built.
| Question | Model | Reports | Limit to state |
|---|---|---|---|
| Which concept is quietest? | Analytical forces, simple structure, point-source noise | Ranked tonal risk | No local geometry; qualitative |
| Which speeds excite a resonance? | Electromagnetic forces on a speed sweep, modal model | Order lines against speed | Structure stiffness and damping inputs |
| Where does the housing radiate? | Mapped forces, structural and acoustic finite elements | Surface vibration and radiated power | Mesh mapping and boundary conditions |
| What does the control change? | Circuit-coupled electromagnetic model with carrier | Switching lines and torque ripple | Controller and converter models |
| What does a sweep look like? | Surrogate on designed force-to-noise runs | Levels inside the sampled range | Range only; gate back to the full model |
A noise model is not a listening test
Where does machine learning help in e-NVH?
Where the model has to be run many times: over the speed and torque map, over slot and pole variants, over control settings. A surrogate trained on a designed set of force-to-noise runs answers inside its range in seconds, tells you when a question falls outside it, and leaves the full model as the gate. The fast Ansys workflow shows that a full speed sweep can already be a matter of minutes; a surrogate extends that speed to design and control variations. Our surrogate-model article, the validation article and the reduced-order model page set out how we train and check them.
From one motor to an NVH workflow your team keeps
The return comes when your engineers run the next winding, slot count or control strategy through the same chain.
- Physics model. CFD and FEA set up once, as templates: geometry clean-up, mesh, solver settings and post-processing that every later run reuses.
- Validation. Mesh and time-step studies, and comparison with tests or full-scale data, so the model's uncertainty is known before it is trusted.
- Automated runs. Scripted runs over the parameters and operating conditions that matter, on your hardware or in the cloud.
- AI surrogate. A machine-learning model trained on those runs answers in seconds and says how sure it is; low-confidence questions go back to the solver.
- Decision tool. Optimisation, trade-off charts or operating guidance, in a form your engineers and operators use every day.
- Field data. Test, trial and monitoring data flow back to recalibrate the model, so it improves with every project instead of being rebuilt.
- A force-to-noise template: your electromagnetic model, the force mapping, the structural model and the acoustic step linked, checked on a case with a known answer.
- A force-mapping tool with a contract: mesh-to-mesh transfer by rotor angle and speed in a versioned, tested file.
- A speed-sweep runner: order lines against speed for the operating range, with the resonances marked.
- A control study: carrier frequency and modulation options against switching noise and performance.
- A validation record: your order spectra against the model, with tolerances set before the run.
- A surrogate with a stated range and a gate back to the full model.
- Handover and training, so your team runs and extends it: our training and software development services.
What should you bring to a first conversation?
- The electromagnetic model, or the machine geometry, windings and materials we can build one from.
- The housing, mounting and bearing information, and any modal test of the stator or the housing.
- The operating map: speed and torque points that matter, and the control and carrier settings.
- Measured order spectra or a recording, even from a similar motor.
- The decision waiting on the answer: a slot and pole choice, a calibration, a sign-off or a build date.
Common questions
Why is radial force more important than tangential force for noise?
What is motor whine?
Is equivalent radiated power enough?
Can simulation replace NVH testing?
If a slot and pole choice, a calibration or an NVH sign-off is waiting on this, send us the electromagnetic model or the machine geometry, the housing and mounting information, the operating map and any order spectra. We reply with the force-to-noise chain we would set up, the validation we would run and what a surrogate could cover. Start with a conversation, or see our NVH for electric motors page and our acoustics and vibration work. Related reading: eVTOL electric motor whine and electric motor thermal simulation.