Electromagnetics & Electrification

Electric motor thermal simulation from loss maps to winding hot spots and duty-cycle limits

The motor meets its torque target on the bench and then runs out of thermal headroom on the duty cycle. Loss maps, coupled electromagnetic and thermal models and a tested hand-over show where the heat is made, where it is stuck and which cooling change pays.

Left, a cutaway simulation view of a cylindrical electric machine with coolant streamlines and hot regions. Right, a loop from electromagnetic solve to loss map, heat transfer and temperatures, loss bars and a temperature curve.
A cutaway machine visualisation beside the loop that turns electromagnetic losses into temperatures.

Electric motor thermal simulation predicts where an electric machine makes its heat, how that heat leaves, and how hot the winding and the magnets get on your duty cycle. We build the chain around your existing electromagnetic and CFD solvers, with a validation record and a surrogate of stated range, so cooling, winding and derating questions are answered before the next prototype or dyno campaign.

The motor reaches its torque target in a short test and then runs out of thermal headroom on the real duty cycle. The winding limit arrives first, or the magnets lose strength as they warm, and the cooling jacket is already fixed in the housing drawing. In the electro-thermal study of a jacket-cooled BMW i3 motor, the authors examine how current density, speed and the cooling heat transfer coefficient affect heat losses, efficiency and maximum temperature. Waiting on the answer: the cooling design freeze, the rating you can promise, the inverter current limit and the next prototype build.

The loop from electromagnetic solve to loss map, heat transfer and temperatures, with temperature feedback on the electromagnetic model Four boxes in a loop. The electromagnetic solve feeds a loss map per region and per group. The loss map feeds the heat-transfer model, which gives temperatures. Temperatures feed back into winding resistance and magnet strength, which changes the electromagnetic solve. Below, four bars for the loss groups that shift between a high-current and a high-speed operating point, and a temperature curve rising towards a limit line. ELECTRIC MOTOR: FROM LOSS TO TEMPERATURE R(T) · Br(T) EM SOLVE flux · current 1 LOSS MAP per region, per group 2 HEAT TRANSFER conduction · CFD 3 TEMPERATURES winding · magnet 4 FOUR LOSS GROUPS HIGH CURRENT · LOW SPEED HIGH SPEED · LOW CURRENT WINDINGSTATORMAGNETSROTOR TEMPERATURE · CYCLE LIMIT YOU DEFINE WINDING HOUSING TIME LOSS SHARES SHIFT WITH SPEED AND TORQUE
  1. EM solve. Currents and magnet field at each speed and torque point.
  2. Loss map. Winding, stator core, magnet and rotor core each get their own heat, not one number.
  3. Heat transfer. Coolant jacket, air gap and end space decide how fast it leaves.
  4. Temperatures. Hotter copper loses more and hotter magnets lose strength, so the loop is iterated.
The chain this article follows. Hover a number to isolate a block, and watch the bars move between two operating points. Illustrative schematic.

What does electric motor thermal simulation have to resolve?

Three things, in a loop. First, the losses: in the COMSOL permanent magnet motor example the electromagnetic model reports four groups, winding, stator core, magnets and rotor core, and current-driven loss sits mainly in the winding while speed-driven loss sits mainly in the magnets and the stator core. Second, the heat paths that carry each group to the coolant. Third, the feedback: winding conductivity and magnet remanence both depend on temperature, so the temperatures change the losses and the torque that produced them, and the solver iterates between the fields.

A model that skips any one of the three can still produce a clean temperature map. It answers a different question from the one your duty cycle asks.

Why does one-way coupling mislead at high current?

The usual shortcut computes losses once, at a fixed temperature, and hands them to the thermal model. The two-way study on the BMW i3 motor passes heat losses one way and the stator, winding, rotor and magnet temperatures back, and compares the result with the conventional one-way algorithm. At high current density the one-way approach "significantly over-predicts" the motor temperature. The abstract does not give the size of the gap, so we quote the direction and not a number.

The consequence is practical. An over-predicted temperature pushes you towards more cooling than the motor needs, or a rating that is lower than it has to be, and it can hide which input really sets the limit. A two-way loop with the same solvers removes that bias; what it costs is the iterations of the loop.

Do you need spatial loss maps, or is a bulk loss enough?

It depends on the decision. An SAE paper maps ohmic, iron, hysteresis and mechanical losses from the electromagnetic mesh onto the thermo-structural mesh with a K-nearest-neighbour method, and compares the temperatures with the traditional bulk-loss approach, which assumes uniform losses for the lamination stack, hairpin and magnets. The authors conclude that bulk losses may be adequate for comparing design options, while lifetime durability needs the spatial distribution of losses and its transient history.

That gives a clean working rule. Use bulk losses to rank concepts quickly. Use the spatial map when the question is a hot spot, a lifetime or a limit. Our templates carry both, so the first answer is fast and the second is ready when the programme needs it.

Where do CFD, thermal networks and reduced models each belong?

Each answers a different question, and a good workflow uses all three. A lumped thermal network is quick enough for a drive cycle: a Siemens Simcenter example uses 18 thermal nodes for a Nissan Leaf motor, takes its losses from the electromagnetic tools, and runs four repeats of the SFTP-US06 cycle, about 40 minutes of driving, in 1 minute. CFD earns its cost where the network needs a number it cannot compute itself: in the example the coolant heat transfer coefficient can come from classical correlations or be imported from CFD, and the authors note that air velocity corrections in the end space would need detailed CFD.

Which motor thermal question needs which model?
QuestionModelReportsLimit to state
Which concept runs coolest?Electromagnetic losses, bulk or by group, into a conduction modelRanked temperaturesUniform-loss assumption
Where is the winding hot spot?Spatial loss map into a 3D thermal modelTemperature field by regionInterface and impregnation inputs
What does the jacket or the end space deliver?CFD of the coolant passage or end-space airHeat transfer coefficientsGeometry and flow conditions of the case
What happens on the duty cycle?Lumped thermal network fed by loss tablesTemperatures over timeParameters from the detailed models and tests
What does a design sweep look like?Surrogate trained on designed runsTemperatures inside the sampled rangeRange only; gate back to the full model
Heat paths in a water-jacketed electric motor, seen in axial half-section A half-section of an electric motor. Copper winding sits in the stator slots with end windings bulging into the end space at each side. The stator core is pressed into a housing with a water jacket. A thin air gap separates the stator from the rotor, which carries magnets. Arrows show heat leaving the winding through the slot insulation, the core and the housing contact into the coolant, and from the end winding into the end-space air. WHERE THE HEAT GOES: AXIAL HALF-SECTION OF A WATER-JACKETED MOTOR COOLANT JACKET IN THE HOUSING LAMINATED STATOR CORE END WINDING END SPACE AIR ROTOR WITH MAGNETS 1 2 3 4 5
  1. Winding and slot. Copper loss is made here and has to cross the slot insulation and impregnation before it reaches iron. The COMSOL tutorial gives the winding insulation its own thin layer, with a conductivity and a thickness, because the model needs both.
  2. Core-to-housing contact. The laminated core is pressed into the housing, and the interface behaves as a thin resistive layer. The COMSOL permanent magnet motor tutorial models it as a thin layer, so it is a parameter to test and, where possible, to calibrate.
  3. Coolant jacket. The heat leaves through a convective boundary. Its coefficient can come from classical laminar or turbulent correlations or be imported from a CFD model of the jacket, as the Siemens Simcenter example describes.
  4. End winding and end space. The end windings sit in air that moves with the rotor. Siemens notes that correcting air velocities in the end space would need detailed CFD.
  5. Air gap and rotor. In the COMSOL tutorial the rotor is cooled only through the air gap, so magnet temperature follows the stator temperature. Magnet temperature also changes remanence, which closes the loop back to the electromagnetic model.
Hover a number: each heat path is tied to the thing a model has to know about it. Illustrative schematic.

The paths in the diagram are the reason this is not a plug-and-play calculation. The COMSOL example represents the laminated core-to-housing contact and the winding insulation as thin layers, sets the water jacket as a convective boundary and the air gap as another, with a modest coefficient, and states its own limits: simplified cooling, a homogenised coil that is valid only when the conductor is much smaller than the skin depth, and results specific to that geometry and operating range. We treat every such input as a parameter with a source and a spread, not as a constant.

How do you know the thermal model is right?

You test it against something you measured. The Siemens example checks its end-winding temperature against a reference transient, and the COMSOL example runs a study of 10 to 240 time frames per mechanical revolution to show that coarse sampling overestimates torque and underestimates losses before it settles on 120. Both are the same habit: say what the model was checked against, and show the number-of-frames or mesh study, not only the result.

For your motor, the record we agree before any run is short: the thermocouple or embedded-sensor data, the duty cycle they were taken on, the tolerance on winding and magnet temperature, and the interface and cooling inputs we are allowed to calibrate. Anything outside that record is reported as a prediction, not as a result.

A thermal model is not a durability sign-off

Simulation does not replace the motor's own test programme, the insulation system and magnet specifications, or your customer's and authority's process. Predicted temperatures depend on loss data, interface and convection inputs, geometry, mesh and calibration. The temperature limit is the one you set from your insulation class and magnet grade; the Siemens example makes the same point and leaves the limit to the user. How far virtual evidence is accepted is agreed with the customer and follows the risk of the decision. Nothing we build certifies a motor.

Where does machine learning earn its place in motor thermal work?

In the layer that has to answer in milliseconds, over many cycles and many designs. The thermal neural network keeps the lumped-parameter structure and learns the nonlinear functions from data, so its states stay physically interpretable. On an electric motor data set it reports a mean squared error of 3.18 K² and a worst-case error of 5.84 K with 64 model parameters. That is one data set and one architecture, so we read it as evidence that structure plus data works, and we test any surrogate on your motor, your range and your cycles before we rely on it.

The same logic applies to a surrogate trained on a designed set of coupled electromagnetic and thermal runs. It answers inside the sampled range, it reports when a question falls outside, and the full model stays behind it as the gate. Our surrogate-model article and the validation and uncertainty article set out how we train and check them, and the reduced-order model and hybrid physics-AI pages show where they fit.

From one thermal study to a workflow your team keeps

The return comes when your engineers run the next winding, cooling jacket or duty cycle through the same chain.

From one simulation study to a permanent workflow A loop of six steps: physics model, validation, automated runs, AI surrogate, decision tool and field data, which feeds back into the physics model. YOUR WORKFLOW Better with every run physics + data + AI, kept in-house 1Physics model 2Validation 3Automated runs 4AI surrogate 5Decision tool 6Field data CFD · FEA TESTS · TRIALS DOE · HPC CLOUD OPTIMISE DECIDE MONITOR RECALIBRATE
  1. Physics model. CFD and FEA set up once, as templates: geometry clean-up, mesh, solver settings and post-processing that every later run reuses.
  2. Validation. Mesh and time-step studies, and comparison with tests or full-scale data, so the model's uncertainty is known before it is trusted.
  3. Automated runs. Scripted runs over the parameters and operating conditions that matter, on your hardware or in the cloud.
  4. AI surrogate. A machine-learning model trained on those runs answers in seconds and says how sure it is; low-confidence questions go back to the solver.
  5. Decision tool. Optimisation, trade-off charts or operating guidance, in a form your engineers and operators use every day.
  6. Field data. Test, trial and monitoring data flow back to recalibrate the model, so it improves with every project instead of being rebuilt.
Physics, validation, automation and AI in one loop that improves with every run. Illustrative schematic.
  • A loss-to-temperature template: your electromagnetic and thermal models linked with a mapping tool, temperature feedback on resistance and magnet strength, and a case with a known answer.
  • A cooling-input register: every interface, impregnation and convection value with its source, its test and its spread.
  • A duty-cycle runner: your drive or load cycles run through a reduced thermal model, with the CFD cases that feed it.
  • A validation record: thermocouple or dyno data against the model, with tolerances set before the run.
  • A surrogate with a stated range and a gate back to the full model.
  • Handover and training, so your team runs and extends it: our training and software development services.

What should you bring to a first conversation?

  • The duty cycle or the operating points that matter, and the temperature limit you work to.
  • Losses you already hold: an efficiency map, loss tables, or the electromagnetic model itself.
  • The cooling concept: jacket, oil, spray or air, with the flow and inlet conditions you can control.
  • Any thermocouple, embedded-sensor or dyno temperature data, even if it is incomplete.
  • The decision waiting on the answer: a cooling freeze, a rating, a current limit or a build date.

Common questions

What is electric motor thermal simulation?
A coupled model of the electromagnetic losses and the heat paths of a motor that predicts winding, magnet and core temperatures on a duty cycle, so cooling and rating decisions are made before the prototype.
Do I need CFD for electric motor cooling?
Not for every question. A thermal network covers the duty cycle. CFD is needed where a heat transfer coefficient or an end-space air velocity cannot be taken from a correlation.
Is one-way coupling ever good enough?
To rank concepts at low load it may be. At high current density a study of a BMW i3 motor reports that one-way coupling significantly over-predicts temperature, so we iterate when the limit matters.
Can simulation replace dyno testing?
No. It narrows what the dyno has to answer and tells you which sensors to fit. Sign-off stays with you and your customer.

If a cooling freeze, a rating or a prototype build is waiting on this, send us the duty cycle, the loss data or electromagnetic model you hold, the cooling concept and any temperature measurements. We reply with the loss-to-temperature chain we would set up, the validation we would run and what a surrogate could cover. Start with a conversation, or see our electric motor cooling page, the motor design page and the article on electric motor whine. Related reading: EV thermal management and inverter thermal design.

OLTRION Engineering

CAE, CFD and simulation team

The OLTRION engineering team runs CFD, FEA and multiphysics simulation programmes for aerospace, automotive, energy and industrial clients, and builds the machine-learning tools that speed them up. These articles come from that project work.

Where this applies

Related capabilities

Have a model that will not converge?

Talk to the engineers who wrote this

Send the geometry, the physics and the decision it has to support. We answer with an approach, not a sales call.

Talk to an engineer